207 resultados para immunoglobulin G

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Antigen-specific circulating immunoglobulin-secreting cells (ISC) migrate to various secondary and tertiary lymphoid tissues. To understand the migration of the cells into the genital tract and its regulation by sex hormones, spleen-derived SG2 hybridoma cells secreting immunoglobulin G2b (IgG2b) and Peyer's patch-derived PA4 hybridoma cells secreting polymer IgA were labelled with (3) H-TdR, and intravenously injected into syngeneic mice of both sexes. Using flow cytometry, surface molecular markers of plasma cells, CD38 and CD138, and adhesion molecules, CD49d, CD162, and CD11a were found to be positive in SG2 and PA4 cells, but CD62L, alpha4beta7 and CD44 were not expressed on these cells. The relative distribution indexes (RDIs) of the cells in genital tract and other tissues were measured. The means of RDIs of SG2 and PA4 cells in female genital tissues were 6.5 and 4.5 times as many as the means in male genital tissues, respectively. The treatment of ovariectomized mice with beta-oestradiol significantly increased the RDIs of PA4 cells in cervix and vagina, but decreased the RDIs of SG2 cells in vagina, horn of uterus, uterus and rectum (P <0.05). Progesterone treatment increased the RDIs of PA4 cells in vagina and rectum (P <0.05). The treatment with testosterone significantly increased the RDIs of SG2 and PA4 cells in epididymis and accessory sex glands (P <0.05). These results demonstrate that the female genital tract is the preferable site for the migration of circulating hybridoma cells to the male genital tract, and sex hormones play an important role in regulation of the migration of circulating ISC to genital tracts.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

An immunosensor interface based on mixed hydrophobic self-assembled monolayers (SAMs) of methyl and carboxylic acid terminated thiols with covalently attached human Immunoglobulin G (hIgG), is investigated. The densely packed and organised SAMs were characterised by contact angle measurements and cyclic voltammetry. The effect of the non-ionic surfactant, Tween 20, in preventing nonspecific adsorption is addressed by ellipsometry during physical and covalent hIgG immobilization on pure and mixed SAMs, respectively. It is clearly demonstrated that nonspecific adsorption due to hydrophobic interactions of hIgG on methyl ended groups is totally inhibited, whereas electrostatic/hydrogen bonding interactions with the exposed carboxylic groups prevail in the presence of surfactant. Results of ellipsometry and Atomic Force Microscopy, reveal that the surface concentration of covalently immobilized hIgG is determined by the ratio of COOH/CH3-terminated thiols in SAM forming solution. Moreover, the ellipsometric data demonstrates that the ratio of bound anti-hIgG/hIgG depends on the density of hIgG on the surface and that the highest ratio is close to three. We also report the selectivity and high sensitivity achieved by chronoamperometry in the detection of adsorbed hIgG and the reaction with its antibody.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

One kind of surface modification method on silicon wafer was presented in this paper. A mixed silanes layer was used to modify silicon surface and rendered the surface medium hydrophobic. The mixed silanes layer contained two kinds of compounds, aminopropyltriethoxysilane (APTES) and methyltriethoxysilane (NITES). A few of APTES molecules in the layer was used to immobilize covalently human immunoglobulin G (IgG) on the silicon surface. The human IgG molecules immobilized covalently on the modified surface could retain their structures well and bind more antibody molecules than that on silicon surface modified with only APTES. This kind of surface modification method effectively improved the sensitivity of the biosensor with imaging ellipsometry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The concept of biosensor based on imaging ellipsometry was proposed ten years ago. Its principle and the methodology as well as some solutions to problems which have to be faced during the development are mentioned. Its properties of phase sensitive, high throughput and fast sampling, as well as label-free, sensitivity better than 1 ng/ml for Immunoglobulin G, and real-time analysis for protein interaction process, etc. provide a potential for applications in biomedicine field. The recent biosensing development with total internal reflection imaging ellipsometry is presented also. [GRAPHICS] An example of 48 protein arrays in matrix. (C) 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Taenia solium metacestode, a larval pork tapeworm, is a causative agent of neurocysticercosis, one of the most common parasitic diseases in the human central nervous system. In this study, we identified a cDNA encoding for a cathepsin L-like cysteine protease from the T solium metacestode (TsCL-1) and characterized the biochemical properties of the recombinant enzyme. The cloned cDNA of 1216 bp encoded 339 amino acids with an approximate molecular weight of 37.6 kDa which containing a typical signal peptide sequence (17 amino acids), a pro-domain (106 amino acids), and a mature domain (216 amino acids). Sequence alignments of TsCL-1 showed low sequence similarity of 27.3-44.6 to cathepsin L-like cysteine proteases from other helminth parasites, but the similarity was increased to 35.9-55.0 when compared to mature domains. The bacterially expressed recombinant protein (rTsCL-1) did not show enzyme activity; however, the rTsCL-1 expressed in Pichia pastoris showed typical biochemical characteristics of cysteine proteases. It degraded human immunoglobulin G (IgG) and bovine serum albumin (BSA), but not collagen. Western blot analysis of the rTsCL-1 showed antigenicity against the sera from patients with cysticercosis, sparganosis or fascioliasis, but weak or no antigenicity against the sera from patients with paragonimiasis or clonorchiasis. (c) 2006 Published by Elsevier B.V.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel sensitive electrochemical immunoassay with colloidal gold as the antibody labeling tag and subsequent signal amplification by silver enhancement is described. Colloidal gold was treated by a light-sensitive silver enhancement system which made silver deposit on the surface of colloidal gold(form Au/Ag core-shell structure), followed by the release of the metallic silver atoms anchored on the antibody by oxidative dissolution of them in an acidic solution and the indirect determination of the dissolved Ag+ ions by anodic stripping voltammetry(ASV) at a carbon fiber microelectrode. The electrochemical signal is directly proportional to the amount of analyte(goat IgG) in the standard or a sample. The method was evaluated by means of a noncompetitive heterogeneous immunoassay of immunoglobulin G(IgG) with a concentration as low as 0.2 ng/ mL. The high performance of the method is related to the sensitive ASV determination of silver(I) at a carbon fiber microelectrode and to the release of a large number of Ag+ ions from each silver shell anchored on the analyte(goat IgG).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An automated biomolecular interaction analysis instrument (BI-Acore) based on surface plasmon resonance (SPR) has been used to determine human immunoglobulin G (IgG) in real time. Polyclonal anti-human IgG antibody was covalently immobilized to a carboxymethyldextran modified gold film surface. The samples of human IgG prepared in HBS buffer were poured over the immobilized surface. The signal amplification antibody was applied to amplify the response signal. After each measurement, the surface was regenerated with 0.1 mol/L H3PO4. The assay was rapid, requiring only 30 min for antibody immobilization and 20 min for each subsequent process of immune binding, antibody amplification and regeneration. The antibody immobilized surface had good response to human IgG in the range of 0.12-60 nmol/L with a detection limit of 60 pmol/L. The same antibody immobilized surface could be used for more than 110 cycles of binding, amplification and regeneration. The results demonstrate that the sensitivity, specificity and reproducibility of amplified immunoassay using real-time BIA technology are satisfactory.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The content and distribution of rare earth(RE) in normal human plasma have been investigated by ultrafiltration, FPLC and ICP-MS methods, The results showed that there are trace RE in normal human plasma, and their contents are in accordance with their abundance, The RE can bond with immunoglobulin G(IgG), transferrin(Tf) and albumin(Alb) species, but mostly bond with Tf.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present paper the rarefied gas how caused by the sudden change of the wall temperature and the Rayleigh problem are simulated by the DSMC method which has been validated by experiments both in global flour field and velocity distribution function level. The comparison of the simulated results with the accurate numerical solutions of the B-G-K model equation shows that near equilibrium the BG-K equation with corrected collision frequency can give accurate result but as farther away from equilibrium the B-G-K equation is not accurate. This is for the first time that the error caused by the B-G-K model equation has been revealed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of using protein A to immobilize antibody on silicon surface for a biosensor with imaging ellipsometry was presented in this study. The amount of human IgG bound with anti-IgG immobilized by the protein A on silicon surface was much more than that bound with anti-IgG immobilized by physical adsorption. The result indicated that the protein A could be used to immobilize antibody molecules in a highly oriented manner and maintain antibody molecular functional configuration on the silicon surface. High reproducibility of the amount of antibody immobilization and homogenous antibody adsorption layer on surfaces could be obtained by this immobilization method. Imaging ellipsometry has been proven to be a fast and reliable detection method and sensitive enough to detect small changes in a molecular monolayer level. The combination of imaging ellipsometry and surface modification with protein A has the potential to be further developed into an efficient immunoassay protein chip.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The g-jitter effects on the thermocapillary convection in liquid bridge of floating half zone were studied by numerical simulation for unsteady and axi-symmetric model in the cylindrical coordinate system. The g-jitter field was given by a steady microgravity field in addition to an oscillatory low-gravity field, and the effects on the flow field, temperature distribution and free surface deformation were analyzed numerically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The g-jitter influence on thermocapillary convection and critical Marangoni number in a liquid bridge of half-floating rone was discussed in the low frequency range of 0.4 to 1.5 Hz in a previous paper. This paper extended the experiments to the intermediate frequency range of 2 to 18 Hz, which htrs often been recorded as vibration environment of spacecrafts. The experiment was completed on the deck of a vibration machine, which gave a periodical applied acceleration to simulate the effects of g-jitter. The experimental results in the intermediate frequency range are different from that in the low frequency range. The velocity field and the shape of the free surface have periodical fluctuations in response to g-jitter. The amplitude of the periodical varying part of the temperature response decreases obviously with increasing frequency of g-jitter and vanishes almost when the frequency of g-jitter is high enough. The critical Marangoni number is defined to describe the transition from a periodical convection in response to g-jitter to an oscillatory convection due to internal instability, and will increase with increasing g-jitter frequency. According to the spectral analysis, it can be found that the oscillatory part of temperature is a superposition of two harmonic waves if the Marangoni number is larger than a critical value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A half floating zone is fixed on a vibrational deck, which supports a periodical applied acceleration to simulate the effect of g-jitter. This paper deals with the effects of g-jitter on the fluid fields and the critical Marangoni number, which describes the transition from a forced oscillation of thermocapillary convection into an instability oscillatory convection in a liquid bridge of half floating zone with top rod heated. The responses of g-jitter field on the temperature profiles and flow pattern in the liquid bridge were obtained experimentally. The results indicated that the critical Marangoni number decreases with the increasing of g-jitter effect and is slightly smaller for higher frequency of g-jitter with fixed strength of applied gravity.